The Litesimo YR/YRQ series products represent cutting-edge technology and economic efficiency, setting a benchmark in the industry. Manufactured in China, these high-performance units offer outstanding energy savings, low noise levels, and minimal vibration, ensuring reliable quality in every application. Designed for easy installation and maintenance, our products are ideal for businesses looking to optimize their operations. As a leading supplier in the market, our factory guarantees excellence and efficiency in each unit, making the Litesimo YR/YRQ series the perfect choice for your needs
  • Power 220kW-1600kW
  • Voltage 6kV,10kV and so on.
  • Mounting IMB3 IMB35
  • Protection IP23
  • Cooling method IC01
  • Duty S1
  • Frequency 50Hz/60Hz
  • Altitude <1000m
  • Temperature -15℃~+40℃
  • Phase three
  • Warranty 3months-1year
  • Place of Origin China

Litesimo YR/YRQ series of products can reach the world's advanced level in terms of technical performance and economic benefits. It has the characteristics of high efficiency, energy saving, low noise, small vibration, reliable quality, easy installation, use and maintenance.
Applications & Usage

Litesimo YRQ series media size IE3 electric motors can drive various kinds of mechanical equipment, such as blowers, compressors, pumps, crushers, and stocker moving machines.

It can serve as the prime movers in coalmines, mechanical industries, power plants, and various industrial enterprises among China electric motor manufacturers.

Technical Standards

Litesimo YRQ series wound rotor 3 phase slip ring motor measures up to the JB563-64 technical standard.

This series motor is designed as a protection type, but they can also be engineered into a tube ventilation type based on customer requirements.

Standard Operating Conditions
  • Must be installed indoors.
  • Altitude must not exceed 1000 meters.
  • Ambient temperature range: 0°C up to 40°C.
  • Air must be clean, non-acid, and non-alkali.
  • Operation is strictly prohibited in explosive or dusty atmospheres.
Tube Ventilation Requirements

When the ambient temperature exceeds the standard limit or the air is unclean, the Tube Ventilation type should be used.

  • Inlet air temperature on both sides of the motor must be between 0°C and 40°C.
  • Air pressure inside the tube and inner motor must be higher than the ambient air pressure.
  • Blower and filter equipment should be installed when necessary.
Important Starting Instruction

Whenever starting the Litesimo YRQ series motor, a rheostat must be equipped inside the stator loop. Winding's short circuit direct start is not allowed.

Frequently Asked Questions (FAQ)

Q1: What are the core performance advantages of the Litesimo YR/YRQ series?
A1: The YR/YRQ series products deliver high efficiency, energy-saving operation, low noise levels, minimal vibration, reliable quality, and simplified installation, usage, and maintenance.
Q2: Which industries and machinery are these motors designed for?
A2: They are ideal for driving blowers, compressors, pumps, crushers, and stocker moving machines. They serve as key prime movers in coalmines, mechanical industries, power plants, and other industrial enterprises.
Q3: What environmental conditions are required for the standard protection style motor?
A3: Standard motors must be installed indoors at an altitude below 1000m, with ambient temperatures between 0°C and 40°C. The air must be clean, non-acid, non-alkali, and free from explosive or dusty elements.
Q4: Under what circumstances should the Tube Ventilation type motor be used?
A4: The Tube Ventilation type is required when the ambient temperature exceeds 40°C or when the surrounding air is unclean. This setup requires internal air pressure to be higher than ambient pressure, alongside necessary blowers and filters.
Q5: Can the Litesimo YRQ series motor be started via direct short circuit?
A5: No. Direct short-circuit starting of the winding is not allowed. A rheostat must be properly equipped inside the stator loop every time the motor is started.