High Voltage YKS Series 6kV/10kV Three-Phase Induction Motors from China Factory & Suppliers
Products Details
YKS series high-voltage water-cooled motor structure and installation type is IMB3, the quota is based on continuous working system (S1) as the benchmark of the continuous quota, motor rated frequency is 50 Hz, rated voltage is divided into 6 KV, 10 KV, other voltage levels or special requirements, in order can be agreed with users.
The rotor of YKS series high voltage motor adopts a squirrel cage structure with reliable cast aluminium or copper conductors.
YKS series high voltage motors can be used to drive various general machinery, such as compressors, pumps, fans, crushers, cutting machines, transport machinery and other mechanical equipment. In mining, machinery industry, power plant and other industrial and mining enterprises as the prime mover. Used to drive blowers, coal mills, rolling mills, winches, etc. should be explained when ordering.
Basic parameters
| Frame size | H355~H800 mm |
| Rated output | 150~8000 kW |
| Rated voltage | 3000V, 3300V, 4160V, 6000V, 6300V, 6600V, 10000V |
| Rated frequency (speed) |
50Hz (3000/1500/1000/750/600/500/425/375/325 r/min)
60Hz (3600/1800/1200/900/720/600/500/450/400 r/min)
|
| No. of poles | 2P, 4P, 6P, 8P, 10P, 12P, 14P, 16P, 18P |
| Mounting methods | Horizontal foot mounted IM1001 (B3) |
| Material of frame/housing | Fabricated in welded steel plate frame |
| Service Factor | 1.00 |
| Insulation Class | F (155℃) |
| Temp. Rising | ΔT=80°K |
| Working Duty | S1 (Continuous) |
| Ambient Temperature | -20°C ~ 40°C |
| Altitude | <=1000 m |
| Ambient humidity | <=90% |
| Protection Class | IP44, IP54, IP55 |
| Cooling | IC81W Self-ventilated with air-to-water heat exchanger, heat exchanger on top of motor |
| Lubricating | Grease lubricated bearings |
| Altitude | PT100 |
| Material of nameplate | Stainless steel |
Motor Type Description
Model Nomenclature: YKS 560 - 4 W
Y
- Asynchronous Motor
KS
- Air Water Cooling
560
- Frame Size: 560mm
4
- Pole
W
- Ambient code, defaulted is indoor. (Special requirement: F1/F2-anti corrosion, W- outdoor, WF1/WF2- outdoor and anti-corrosion)
Frequently Asked Questions
What is the cooling method used in the YKS series motor?
The YKS series high-voltage motor features an IC81W cooling method. It is self-ventilated with an air-to-water heat exchanger mounted on top of the motor.
What are the primary applications for YKS series motors?
These motors are designed to drive general machinery, including compressors, pumps, fans, crushers, cutting machines, and transport machinery. They are widely used in mining, power plants, and machinery industries.
What rotor structure does the YKS series motor use?
The rotor uses a reliable squirrel cage structure engineered with cast aluminum or copper conductors.
What does the "W" in the model description represent?
The "W" stands for the ambient code. By default, the motor is designed for indoor use. "W" specifies outdoor use, whereas "F1/F2" indicates anti-corrosion, and "WF1/WF2" indicates combined outdoor and anti-corrosion protection.
What are the standard installation and mounting specifications?
The standard installation type is IMB3, and the mounting method is horizontal foot-mounted IM1001 (B3).
What are the insulation and temperature rise standards?
The YKS series motor is built with Class F insulation (155°C) and is rated for a temperature rise of ΔT=80°K.